NEW

Mindray TV50 Turbine-Driven Transport Ventilator

Mindray · Transport Ventilation

Intensive care, on the move.

A 4.5 kg turbine-driven transport ventilator for adult, paediatric and infant patients, giving invasive, non-invasive and oxygen therapy without compressed air.

  • Weight≈4.5 kg
  • Peak flow≥210 L/min turbine
  • BatteryUp to 10 h (2 batteries)
  • PatientsAdult · paediatric · infant
CEFor healthcare professionals

Quote-based pricing for clinics, hospitals and healthcare providers across the UAE & GCC.

Mindray

Intensive care, on the move.

The TV50 carries ICU-style ventilation into ambulances, aircraft and in-hospital transfers. Its built-in turbine delivers peak flows of at least 210 L/min, so it runs without a compressed-air supply and supports non-invasive ventilation, while oxygen is set from 21 to 100%. The 7-inch touchscreen mirrors Mindray's bedside ventilators, and the mode set includes AMV adaptive ventilation and a one-touch CPRV mode for resuscitation. Hot-swappable batteries give up to 10 hours with two batteries, and the unit is tested to EN 1789, EN 13718-1 and RTCA DO-160G.

Key specifications

TypeTurbine-driven transport ventilator · no compressed air required · Class IIb
Ventilation modesV-A/C · P-A/C · V-SIMV · P-SIMV · DuoLevel · CPAP/PSV · VS · APRV · PRVC · PRVC-SIMV · AMV · CPRV · NIV · O₂ therapy
SettingsTidal volume adult 100–4,000 mL, paediatric 20–300 mL, neonatal 20–100 mL · rate 1–100/min · I:E 1:10 to 4:1 · PEEP off to 50 cmH₂O · O₂ 21–100% · O₂ therapy flow 2–80 L/min
BlowerMaximum flow ≥210 L/min · maximum pressure ≥60 cmH₂O · leak compensation up to 65 L/min (adult)
Oxygen supplyHigh-pressure O₂ 0.28–0.65 MPa (NIST or DISS) or low-pressure O₂ ≤0.1 MPa, ≤15 L/min · non-consuming O₂ sensor · real-time O₂ consumption
MonitoringOptional mainstream EtCO₂ 0–150 mmHg · pressure, flow, volume and CO₂ waveforms · loops · 120 h trends
Display7-inch capacitive touchscreen, 800 × 480 px · auto brightness · outdoor mode
Dimensions222 × 294 × 210 mm (L × H × W)
Weight≈4.5 kg (excluding trolley)
Power100–240 V AC · 12–28 V DC · one or two Li-ion batteries 14.4 V, 6,600 mAh · 300 min per battery, 600 min with two · hot-swappable
EnvironmentOperating −20 to 50 °C, 5–95% RH · storage −20 to 60 °C · 37.6–110 kPa · automatic altitude compensation up to 7,600 m
RobustnessIP34 · 75 cm drop on 6 sides · 20 G force resistance
StandardsISO 80601-2-12 · ISO 80601-2-84 · IEC 60601-1-12 · EN 1789 · EN 13718-1 · RTCA DO-160G · MIL-STD-810G
ConnectivityUSB · Ethernet · Wi-Fi · Bluetooth · 5G (optional) · data to hospital CMS or ePCR

Why the Mindray TV50

No air supply needed

A built-in turbine with at least 210 L/min peak flow drives invasive and non-invasive ventilation from oxygen alone, with FiO₂ set from 21 to 100%.

Bedside modes in transit

The same modes as Mindray's ICU ventilators, including APRV, PRVC and AMV adaptive minute ventilation, so therapy continues unchanged during transfer.

CPRV at one touch

A dedicated CPR ventilation mode recalls preconfigured settings for resuscitation, and mainstream EtCO₂ helps confirm airway position.

Power and oxygen planning

Hot-swappable batteries run up to 10 hours with two batteries, and the screen shows remaining battery and real-time oxygen consumption.

Tested for the road and air

Meets EN 1789 and EN 13718-1, RTCA DO-160G for aircraft, with IP34 protection and a 75 cm drop test.

Where it is used

Intensive care and in-hospital transfers, road ambulances, and helicopter and fixed-wing air ambulances, by trained clinical staff.

In the box

TV50 ventilator. Batteries, patient circuits, O₂ hoses, mainstream CO₂ module, mounting handle, fixed base, trolley or cylinder carrier are configured per order. Pack sizes and configurations are confirmed with the quotation.

Clearance & compliance

CE
For healthcare professionals. Supplied to hospitals, clinics, EMS providers and qualified practitioners. Clinical training, evaluation units and tender documentation are available on request.

CE marked, notified body TÜV SÜD Product Service (CE 0123), per the TV50 Operator's Manual (May 2023); Class IIb per Mindray's EU datasheet; Mindray's MDR QMS certificate G10 044751 0176 Rev. 06 covers its Class IIb ventilators. Supplied subject to registration in each destination country (MOHAP, DoH, DHA, SFDA or the equivalent authority). Certificates, declarations of conformity, IFUs and registration documents are provided with every quotation. Specifications are indicative and subject to manufacturer change.

Where a country has an official agent or authorised distributor, we source the item through it — or directly from the manufacturer if necessary. Product names, trademarks and images belong to their respective owners.

Questions

Is the Mindray TV50 available in the UAE and the GCC?

KGG sources the TV50 on request for hospitals and ambulance services in the UAE, Saudi Arabia, Qatar, Kuwait, Bahrain and Oman. It is supplied subject to registration in each destination country, and availability is confirmed with each quotation.

How do I get a price?

Add the TV50 to your quote list or use Request a quote. We reply with pricing, lead time and the documents for your country, and can quote batteries, circuits, the CO₂ module and a trolley or base with it.

Does it need compressed air?

No. The integrated turbine generates the flow, so the TV50 only needs an oxygen source (high- or low-pressure) when FiO₂ above 21% is required.

TV50 or TV80?

The TV50 is Mindray's compact 4.5 kg transport ventilator. The TV80 is the larger model in the same series; ask us for a side-by-side comparison for your fleet.

Which patients can it ventilate?

Adult, paediatric and infant patients, with tidal volumes from 20 mL up to 4,000 mL depending on patient type, invasively or non-invasively.

Will it cope with Gulf heat?

Mindray rates the TV50 for operation from −20 to 50 °C and storage up to 60 °C, with 5–95% humidity. Avoid leaving it in direct sun in a parked vehicle.

Request a quote

Get pricing for the Mindray TV50.

Tell us the quantity, delivery city and whether you are ordering for a facility, a team or a patient. We reply with pricing, lead time and the regulatory documents for your country.

← All transport medicine

Additional information

Brand

Mindray

Made in

China (Shenzhen Mindray)

Device type

Transport Ventilation

Regulatory

CE

Weight

≈4.5 kg

Supply

For healthcare professionals

By placing this order, you confirm that you have read and agree to our:

Payment Policy
Secure payments with bank transfer or COD. 50% deposit + balance before shipment.

Return & Refund Policy
No returns on change of mind. Report damaged or incorrect items within 3 days.

Explore further

Where this product fits

Collections that include it

Next steps

Delivery across the GCC

Supplied from Abu Dhabi to all six GCC countries

KGG delivers door to door within the UAE and ships to Saudi Arabia, Qatar, Kuwait, Bahrain and Oman through trusted logistics partners. Tell us your country and delivery city when you request a quote.

  • Quotation or proforma invoice usually within one business day.
  • Typical GCC transit: 3 to 5 business days after dispatch.
  • The Incoterm (EXW, FOB, CIF, DAP or DDP) is stated on every quotation.
  • Commercial invoice, packing list, certificate of origin and product certificates for customs clearance.
  • Registration status for your country confirmed on the quotation.
  • Invoices in AED, USD or SAR; goods carry the manufacturer’s warranty.

Shipping Policy · Country guides for the GCC