Senseonics Eversense 365 One-Year Implantable CGM System

Eversense · Continuous Glucose Monitoring

One sensor. One year.

A fully implantable continuous glucose monitor for adults with diabetes: one sensor placed under the skin of the upper arm measures glucose for up to a year.

  • Sensor lifeUp to 365 days
  • CalibrationOnce weekly after day 13
  • ReadingsEvery 5 minutes
  • Age18 years and older
FDACEFor healthcare professionals

Quote-based pricing for clinics, hospitals and healthcare providers across the UAE & GCC.

Eversense

One sensor. One year.

Eversense 365 pairs a small sensor, inserted under the skin of the upper arm by a healthcare provider in a brief in-office procedure, with a removable smart transmitter worn over it. The transmitter sends glucose data to the Eversense app every five minutes and gives on-body vibration alerts even when the phone is not nearby. Fingerstick calibration is needed once a week after day 13, and the transmitter can be taken off and reattached without wasting the sensor.

Key specifications

IndicationContinuous glucose measurement for up to one year in people with diabetes aged 18 and older · replaces fingerstick testing for treatment decisions, with the exceptions in the labelling
SensorImplanted under the skin of the upper arm · inserted and removed by a healthcare provider
Sensor lifeUp to 1 year (365 days)
CalibrationFingerstick once a week after day 13 · also when symptoms do not match readings or when taking tetracycline-class medicines
TransmitterRemovable smart transmitter worn over the sensor · on-body vibration alerts · stores data when out of range
Data intervalGlucose data sent to the app every 5 minutes
Water resistanceTransmitter IP67: submersible to 1 m / 3.2 ft for up to 30 minutes
AdhesiveSilicone-based patch changed daily · 390 patches included (perforated white and discreet clear)
CompatibilityiOS and Android smartphones · Apple Watch (sold separately)
Data sharingEversense NOW app for remote followers · DMS online data account
MRIRemove the transmitter and keep it outside the MRI room; follow labelling for the sensor
Pump integrationWorks with the twiist automated insulin delivery system (USA only)
SupplyPrescription device

Why the Eversense 365

A year per sensor

One implanted sensor measures glucose for up to 365 days, compared with the 10 to 15 days of conventional wearable sensors, so there is no fortnightly sensor change.

Remove without waste

The smart transmitter can be taken off and put back at any time except during calibration, without wasting the sensor. No glucose data is collected while it is off.

Alerts on the body

The transmitter vibrates to alert the wearer even when the phone is out of reach. Senseonics reports almost no false alerts from compression lows during sleep.

Weekly calibration

Fingerstick calibration drops to once a week after day 13, compared with once a day for the previous Eversense E3.

Gentle on skin

The adhesive is silicone-based and changed daily over the transmitter, not over a sensor wire, and Senseonics reports almost no skin reactions.

Where it is used

Diabetes and endocrinology clinics, with sensor insertion and removal performed by a trained healthcare provider in an outpatient setting.

In the box

Smart transmitter with its charging cable and adapter, and a supply of adhesive patches; the sensor and insertion kit are supplied for the clinic procedure. Pack sizes and configurations are confirmed with the quotation.

Clearance & compliance

FDACE
For healthcare professionals. Supplied to hospitals, clinics, EMS providers and qualified practitioners. Clinical training, evaluation units and tender documentation are available on request.

FDA cleared September 2024 as an integrated CGM (iCGM), prescription only (Senseonics SEC filings) · CE marked under the EU MDR (January 2026). Supplied subject to registration in each destination country (MOHAP, DoH, DHA, SFDA or the equivalent authority). Certificates, declarations of conformity, IFUs and registration documents are provided with every quotation. Specifications are indicative and subject to manufacturer change.

Where a country has an official agent or authorised distributor, we source the item through it — or directly from the manufacturer if necessary. Product names, trademarks and images belong to their respective owners.

Questions

Is the Eversense 365 available in the UAE and the GCC?

KGG sources Eversense 365 on request for diabetes centres and hospitals in the UAE, Saudi Arabia, Qatar, Kuwait, Bahrain and Oman, supplied subject to registration in each destination country. Senseonics sells directly in the USA and Europe and through distributors elsewhere, so availability is confirmed with each quotation.

How is the sensor placed?

A healthcare provider inserts the sensor under the skin of the upper arm in a brief in-office procedure, and removes it the same way at the end of its life. Clinics need trained staff for both steps.

Does it still need fingerstick tests?

Yes, for calibration once a week after day 13. A fingerstick is also needed when symptoms do not match the CGM reading and when the user is taking tetracycline-class medicines.

How is it different from the Eversense E3?

The E3 sensor lasts 180 days with daily calibration after day 21. Eversense 365 doubles sensor life to a full year and needs calibration only once a week.

Can the transmitter get wet?

Yes. The transmitter is rated IP67 and can be submerged to 1 m for up to 30 minutes, so showering and swimming are fine. Exposure beyond this can damage it.

How do I get a price?

Add Eversense 365 to your quote list or use Request a quote. We reply with pricing, lead time and the documents available for your country.

Request a quote

Get pricing for the Eversense 365.

Tell us the quantity, delivery city and whether you are ordering for a facility, a team or a patient. We reply with pricing, lead time and the regulatory documents for your country.

← All diabetes care

Additional information

Brand

Eversense

Made in

USA (company headquarters; country of manufacture not stated)

Device type

Continuous Glucose Monitoring

Regulatory

FDA · CE

Supply

For healthcare professionals

By placing this order, you confirm that you have read and agree to our:

Payment Policy
Secure payments with bank transfer or COD. 50% deposit + balance before shipment.

Return & Refund Policy
No returns on change of mind. Report damaged or incorrect items within 3 days.

Explore further

Where this product fits

Collections that include it

Next steps

Delivery across the GCC

Supplied from Abu Dhabi to all six GCC countries

KGG delivers door to door within the UAE and ships to Saudi Arabia, Qatar, Kuwait, Bahrain and Oman through trusted logistics partners. Tell us your country and delivery city when you request a quote.

  • Quotation or proforma invoice usually within one business day.
  • Typical GCC transit: 3 to 5 business days after dispatch.
  • The Incoterm (EXW, FOB, CIF, DAP or DDP) is stated on every quotation.
  • Commercial invoice, packing list, certificate of origin and product certificates for customs clearance.
  • Registration status for your country confirmed on the quotation.
  • Invoices in AED, USD or SAR; goods carry the manufacturer’s warranty.

Shipping Policy · Country guides for the GCC