NEW

Getinge Flow-i Anaesthesia System with Automatic Gas Control

Getinge · Anaesthesia Workstation

Low flow. Full control.

A high-end anaesthesia system from Getinge with Servo gas modules, the Volume Reflector rebreathing system and optional Automatic Gas Control, for neonatal to adult patients in complex and general surgery.

  • Display15-inch touchscreen
  • Low flowFGF from 0.1 l/min
  • BatteryApprox. 90 minutes
  • VersionsC20 · C30 · C40
FDAFor healthcare professionals

Quote-based pricing for clinics, hospitals and healthcare providers across the UAE & GCC.

Getinge

Low flow. Full control.

Flow-i is the most advanced machine in Getinge's Flow family of anaesthesia systems, built by Maquet Critical Care in Sweden. Its Flow Core Technology combines the Maquet Volume Reflector rebreather with Servo gas modules that adjust pressure and flow within every breath, with up to 200 l/min inspiratory flow, tidal volumes of 20–2,000 ml and pressures up to 120 cmH2O. Electronic vaporisers, fresh gas flows down to 0.1 l/min and optional Automatic Gas Control (AGC) make low-flow anaesthesia routine, while O2Guard and MAC Brain are standard. It comes on a cart with drawers (C20), as a height-adjustable model (C30) or ceiling-mounted for the hybrid OR (C40).

Key specifications

TypeSoftware-controlled, semi-closed inhalation anaesthesia system with integrated ventilator (FDA 510(k) summary K191027)
PatientsNeonatal to adult (FDA indications for use) · Getinge describes Flow-i as suitable for highly specialised procedures such as paediatric and robotic surgery
Ventilation technologyFlow Core Technology: Maquet Volume Reflector rebreather with Volume Reflector Indicator · Servo gas modules adjusting pressure and flow within every breath · up to 200 l/min inspiratory flow
Volume and pressureTidal volume 20–2,000 ml · pressure 0–120 cmH2O (standard on Flow-i; optional on Flow-c and Flow-e)
Ventilation modesVolume Control · Pressure Control · PRVC · Pressure Support with backup · SIMV (VC or PC with Pressure Support) · manual ventilation · additional fresh gas outlet · emergency ventilation (Flow family SW 4.7)
AgentsSevoflurane, desflurane, isoflurane and/or nitrous oxide
VaporisersElectronic vaporisers in two active slots · 300 ml each · refillable during use · no heating time for desflurane · included in the automated system check
Low-flow toolsFresh gas flow from 0.1 l/min · Volume Reflector Indicator (FGF to minute-volume ratio) · Automatic Gas Control option (set target inspired O2, end-tidal agent and speed)
Safety and decision supportO2Guard active hypoxia prevention and MAC Brain as standard · lung recruitment manoeuvre option (automatic stepwise or manual, EIP, PEEP and Cdyn in real time) · Pause function
Gas monitoringIntegrated patient gas analyser (AION Platinum with built-in O2 sensor, per FDA 510(k) K191027)
Display15-inch touchscreen, tiltable and 360° rotatable · 170° rotatable arm with dimmable LED lights · quick-access presets for agent, O2 and fresh gas flow
ConfigurationsC20 mobile with 2–3 drawers · C30 height-adjustable with 1 drawer · C40 ceiling-mounted pendant with 1–2 drawers
Breathing systemSmall system volume, approx. 2.7 l, for fast wash-in and wash-out · only 7 parts dismantled for cleaning
Power and sizeBattery backup approx. 90 minutes · footprint 99 × 69 cm · backup gas option 2+1 cylinders
ConnectivityPatient monitor, HIS and PDMS connection via FCI protocol or HL7 · FleetView connected service · active and passive agent capture compatible (passive as option)

Why the Flow-i

ICU-grade ventilation

Servo gas modules deliver up to 200 l/min inspiratory flow and the Volume Reflector rebreather keeps gas delivery precise. Getinge says this reduces the need for an ICU ventilator in the OR, even for challenging patients.

Low flow, automated

With Automatic Gas Control the clinician sets target inspired oxygen, end-tidal agent and speed, and the system makes the adjustments. Getinge cites a study showing sevoflurane wastage reduced by up to 58%.

Active hypoxia prevention

If the inspired oxygen level drops below 21%, O2Guard overrules the settings and increases the oxygen flow. Getinge describes it as the only system of its kind; it is standard on every Flow machine.

Dosing with MAC Brain

MAC Brain uses mathematical models to visualise the difference in agent effect between the lungs and the brain, giving decision support for anaesthetic dosing. Optional lung recruitment manoeuvres help counter atelectasis.

Three ways to install

Choose the C20 for extra storage with two or three drawers, the height-adjustable C30 to match each user's working position, or the ceiling-mounted C40, which frees the floor and eases cleaning in hybrid ORs.

Where it is used

Hospital operating rooms for complex and general cases, including paediatric, neonatal and robotic surgery, and hybrid ORs with the ceiling-mounted C40. Not for use in MRI environments.

In the box

Flow-i anaesthesia system in the chosen version (C20, C30 or C40) with 15-inch control panel, breathing system, electronic vaporiser(s) and CO2 absorber, as configured by Getinge. Automatic Gas Control, lung recruitment, backup gas, agent capture and mounting accessories are options. Pack sizes and configurations are confirmed with the quotation.

Clearance & compliance

FDA
For healthcare professionals. Supplied to hospitals, clinics, EMS providers and qualified practitioners. Clinical training, evaluation units and tender documentation are available on request.

FDA 510(k) cleared: K191027 (Flow-i/Flow-c/Flow-e Anesthesia System 4.7, 18 Mar 2020) and earlier K102182 (Maquet FLOW-i C20/C30, 9 May 2011), K133958 and K160665 · CE marking and EU class not stated on Getinge's public Flow-i pages. Supplied subject to registration in each destination country (MOHAP, DoH, DHA, SFDA or the equivalent authority). Certificates, declarations of conformity, IFUs and registration documents are provided with every quotation. Specifications are indicative and subject to manufacturer change.

Where a country has an official agent or authorised distributor, we source the item through it — or directly from the manufacturer if necessary. Product names, trademarks and images belong to their respective owners.

Questions

Is the Flow-i available in the UAE and the GCC?

KGG sources the Flow-i on request for hospitals and surgical centres in the UAE, Saudi Arabia, Qatar, Kuwait, Bahrain and Oman, supplied subject to registration in each destination country. Availability is confirmed with each quotation.

How do I get a price?

Add it to your quote list or use Request a quote. We reply with pricing, lead time and the documents for your country, and we can quote the C20, C30 or C40 version with Automatic Gas Control, lung recruitment and other options.

What is the difference between Flow-i, Flow-c and Flow-e?

Flow-i offers the widest settings as standard (tidal volume 20–2,000 ml, pressure up to 120 cmH2O), two vaporiser slots and three versions, including height-adjustable and ceiling-mounted. Flow-c is the compact model with one active slot; Flow-e is the extended workstation. All share the same interface, O2Guard and MAC Brain.

Which anaesthetic agents can it deliver?

Sevoflurane, desflurane and isoflurane through electronic vaporisers, with or without nitrous oxide. Each vaporiser holds 300 ml, can be refilled during use and needs no heating time for desflurane; two vaporisers can sit in the active slots.

Can it ventilate neonates and small children?

Yes. The indications cover neonatal to adult patients, tidal volumes start at 20 ml, and Getinge describes Flow-i as suitable for paediatric surgery; it has published a case study of a 393 g neonate. Breathing circuits are chosen to suit the patient size.

What happens if mains power or the gas supply fails?

Getinge states a battery backup of approximately 90 minutes. Backup gas cylinders can be added as an option (2+1 configuration on Flow-i), and an emergency ventilation function is available.

Request a quote

Get pricing for the Flow-i.

Tell us the quantity, delivery city and whether you are ordering for a facility, a team or a patient. We reply with pricing, lead time and the regulatory documents for your country.

← All acute & critical care

Additional information

Brand

Getinge

Made in

Sweden

Device type

Anaesthesia Workstation

Regulatory

FDA

Supply

For healthcare professionals

By placing this order, you confirm that you have read and agree to our:

Payment Policy
Secure payments with bank transfer or COD. 50% deposit + balance before shipment.

Return & Refund Policy
No returns on change of mind. Report damaged or incorrect items within 3 days.

Explore further

Where this product fits

Collections that include it

Next steps

Delivery across the GCC

Supplied from Abu Dhabi to all six GCC countries

KGG delivers door to door within the UAE and ships to Saudi Arabia, Qatar, Kuwait, Bahrain and Oman through trusted logistics partners. Tell us your country and delivery city when you request a quote.

  • Quotation or proforma invoice usually within one business day.
  • Typical GCC transit: 3 to 5 business days after dispatch.
  • The Incoterm (EXW, FOB, CIF, DAP or DDP) is stated on every quotation.
  • Commercial invoice, packing list, certificate of origin and product certificates for customs clearance.
  • Registration status for your country confirmed on the quotation.
  • Invoices in AED, USD or SAR; goods carry the manufacturer’s warranty.

Shipping Policy · Country guides for the GCC